| SKU: | |
|---|---|
| Availability: | |
| Quantity: | |
| PDF Export | |
HALANSM® HLN-G901Y is a direct replacement water-cooling tube for Kjellberg G901Y (.11.848.201.142), compatible with HiFocus130i, HiFocus160i, and HiFocus280i plasma systems using PerCut450M “G” type torches. Rated 20–200A, it is the designated low-amperage cooling component in Kjellberg’s PerCut450M stack, delivering coolant directly to the electrode tip to prevent overheating and premature cathode failure. Constructed from copper alloy with silver for enhanced thermal conductivity, G901Y ensures stable arc root and ISO 9013 Class 1 cut quality under sustained low-to-mid amperage O₂ cutting.
G901Y / .11.848.201.142 (Kjellberg)
HALANSM®
HLN-G901Y
HALANSM®
Plasma Consumables — Kjellberg HiFocus Series
Product Data Sheet — HLN-G901Y
HALANSM® HLN-G901Y Cooling Tube
for Kjellberg HiFocus130i / 160i / 280i — 20–200A
SUMMARY:
HALANSM® HLN-G901Y is a direct replacement water-cooling tube (OEM cross-reference G901Y / .11.848.201.142) engineered for Kjellberg HiFocus130i, HiFocus160i, and HiFocus280i plasma systems using PerCut450M “G” type torches at 20–200A. Constructed from copper alloy with silver, it delivers coolant directly to the electrode tip to prevent overheating and premature cathode failure. G901Y is the designated low-amperage cooling tube in Kjellberg’s PerCut450M stack, positioned at the base of the consumable assembly.
HALANSM® HLN-G901Y is a direct replacement water-cooling tube with OEM part number G901Y (.11.848.201.142), compatible with Kjellberg HiFocus130i, HiFocus160i, and HiFocus280i plasma cutting systems operating at 20–200A with PerCut450M “G” type torches. The cooling tube is constructed from copper alloy with silver, engineered to Kjellberg’s dimensional tolerances for the PerCut450M low-to-mid amperage platform. It is rated for 20–200A O₂, N₂, Air, and F5 plasma service, delivering coolant directly to the electrode tip to prevent overheating and electrical short circuiting.
The HLN-G901Y installs as the base component of the consumable stack — inserted first into the torch body, then the G002Y or G003Y cathode threads onto it, followed by the G101 gas guide, G2006Y–G2016Y nozzle, G3004/G3028 nozzle cap, G4015/G4020/G4030 swirl gas cap, and finally the G501 protective cap. An improperly sized or damaged cooling tube causes premature electrode failure due to overheating — making G901Y selection critical for low-to-mid amperage O₂ cutting uptime.
HALANSM® Part Number: HLN-G901Y
OEM Cross-Reference: G901Y / .11.848.201.142 (Kjellberg)
Component Type: Water-Cooling Tube (Coolant Delivery)
Material: Copper alloy with silver
Amperage Range: 20–200A
Compatible Systems: Kjellberg HiFocus130i, HiFocus160i, HiFocus280i
Compatible Torch: PerCut450M “G” type
Cooling Method: Water-cooled (Kjellfrost fluid cooling system)
Plasma Gas: O₂ (primary), Air, F5, N₂
Swirl Gas: O₂, N₂, Air
Function: Delivers coolant to electrode tip; prevents overheating & short circuiting
Packaging: 1 pc/anti-static bag, 10 pcs/box
Supply Capacity: 1,000–3,000 pcs/week
Installation Tool: Kjellberg tool 60.01 (threaded insertion)
HALANSM® PN | OEM PN | Component | Current | Compatible System |
HLN-G901Y | G901Y (.11.848.201.142) | Cooling Tube | 20–200A | HF130i/160i/280i + PerCut450M |
HLN-G931Y | G931Y (.11.848.401.142) | Cooling Tube | 280–400A | HF280i/360i/440i + PerCut450M |
HLN-G902Y | G902Y (.11.852.201.142) | Cooling Tube | PerCut451M | HF280i/360i/440i + PerCut451M |
HLN-G941 | G941 | Cooling Tube (Ar/H₂) | — | HF280i/360i/440i + PerCut451M |
HLN-G002Y | G002Y (.11.848.221.300) | Cathode O₂ | 20–200A | HF130i/160i/280i + PerCut450M |
⚠️ Critical: G901Y is rated 20–200A. For 280–400A systems (HiFocus360i/440i), use HLN-G931Y instead. For Ar/H₂ HiFinox cutting, use HLN-G941 cooling tube.
# | Step | Component | OEM PN | HALANSM® |
1 | Base install | Cooling Tube | G901Y (.11.848.201.142) | HLN-G901Y |
2 | Thread onto cooling tube | Cathode (Electrode) | G002Y (.11.848.221.300) | HLN-G002Y |
3 | Insert into nozzle | Gas Guide / Swirl Ring | G101 (.11.848.221.145) | HLN-G101 |
4 | Thread onto torch body | Nozzle (by amp) | G2006Y–G2016Y | HLN-G201X series |
5 | Thread onto nozzle | Nozzle Cap | G3004 / G3028 | HLN-G3004 / HLN-G3028 |
6 | Thread onto torch body | Swirl Gas Cap | G4015 / G4020 / G4030 | HLN-G40XX |
7 | Hand-tight final cap | Protective Cap | G501 (.11.848.201.081) | HLN-G501 |
Nozzle Selection by Amperage (O₂):
Amperage | Nozzle OEM PN | HALANSM® Equivalent | Application |
25A | G2006Y (.11.848.221.406) | HLN-G2006Y | Thin sheet |
35A | G2007Y (.11.848.221.407) | HLN-G2007Y | Light gauge |
80A | G2010Y (.11.848.221.410) | HLN-G2010Y | General fab |
120A | G2012Y (.11.848.221.412) | HLN-G2012Y | Medium plate |
160A | G2014Y (.11.848.221.414) | HLN-G2014Y | Heavy plate |
200A | G2016Y (.11.848.221.416) | HLN-G2016Y | Max capacity |
INSTALLATION TIP:
G901Y is installed FIRST and typically LEFT IN PLACE during routine consumable changes — only remove if damaged. Use Kjellberg tool 60.01 to thread into torch body until finger-tight plus 1/4 turn. Never overtighten.
✅ IDEAL FOR
• 20–80A O₂ cutting on HiFocus130i — 0.5–6mm mild steel at 1500–6000mm/min; G901Y delivers rated coolant flow to keep G002Y cathode tip below critical temperature, preventing premature hafnium emitter erosion.
• 80–120A production cutting on HiFocus160i/280i — 6–12mm mild steel at 1000–2000mm/min; G901Y + G2010Y/G2012Y nozzle + G002Y cathode stack maintains stable arc at 100% duty cycle for job shop and fabrication work.
• Contour Cut / keyhole cutting at 120–200A O₂ — small-hole cutting without secondary operations on HiFocus280i with PerCut450M; G901Y’s coolant channel supports the higher energy density required for keyhole penetration.
❌ NOT RECOMMENDED FOR
• HiFocus360i/440i at 280–400A — G901Y is rated 20–200A. For these systems, use HLN-G931Y (280–400A cooling tube) to match coolant flow dynamics and prevent electrode overheating.
• Ar/H₂ HiFinox cutting on PerCut451M — G901Y is the O₂/Air cooling tube. For Ar/H₂ plasma, use HLN-G941 cooling tube specifically engineered for HiFinox gas chemistry.
✔ Copper alloy with silver construction: Enhanced thermal conductivity vs standard copper ensures maximum coolant-to-tip heat transfer, preventing electrode overheating at sustained 20–200A loads.
✔ OEM-equivalent dimensional accuracy: Machined to G901Y (.11.848.201.142) tolerances for direct drop-in fit in PerCut450M torch; seamless integration with G002Y cathode.
✔ Prevents premature cathode failure: Properly sized internal coolant channel eliminates hot spots that cause hafnium emitter cratering and double arcing; extends G002Y electrode lifespan.
✔ High-volume supply: Manufacturing capacity of 1,000–3,000 pcs/week; 5–10 business day lead time for in-stock orders; MOQ 1 pc.
✔ Quality inspection: Every HLN-G901Y undergoes pressure testing and dimensional inspection before shipment; ISO 9001 certified manufacturing process.
✔ Cost-efficient uptime insurance: At ~$5–15/unit vs $50–150 cathode replacement cost, a quality cooling tube is the highest-ROI component in the PerCut450M stack.
Yes. HALANSM® HLN-G901Y is a direct replacement for Kjellberg G901Y (.11.848.201.142), fully compatible with HiFocus130i, HiFocus160i, and HiFocus280i plasma systems using the PerCut450M “G” type torch at 20–200A. It installs as the base component: G901Y cooling tube → G002Y cathode → G101 gas guide → G2010Y/G2012Y nozzle → G3004/G3028 nozzle cap → G4020/G4030 swirl gas cap → G501 protective cap.
No. G901Y (.11.848.201.142) is the low-amperage cooling tube rated 20–200A for PerCut450M “G” type torches. G931Y (.11.848.401.142) is the high-amperage cooling tube rated 280–400A for the same PerCut450M platform. They are not interchangeable — installing G901Y in a 280–400A stack causes coolant flow mismatch, leading to electrode overheating and premature failure.
Catastrophic cathode failure. An improperly sized or damaged cooling tube causes premature electrode failure due to overheating and electrical short circuiting. Symptoms include: rapid hafnium emitter cratering, double arcing, inconsistent arc initiation, and ultimately cathode destruction within 50–100 arc starts instead of the normal 200–400. Always inspect G901Y for cracks, coolant leaks, or thread damage during consumable changes.
Only on O₂/Air systems. HLN-G901Y is the cooling tube for O₂ and Air plasma. For Ar/H₂ HiFinox cutting on PerCut451M, use HLN-G941 cooling tube, which is specifically engineered for Ar/H₂ gas chemistry and cooling fluid compatibility. Using G901Y in Ar/H₂ service may cause coolant contamination and accelerated corrosion.
Step-by-step: (1) Remove used consumables: unscrew protective cap (G501) and swirl gas cap (G4020/G4030) from torch body. (2) Use socket wrench (tool 60.02) to remove nozzle cap, nozzle, and extract gas guide from nozzle. (3) Unscrew cathode (G002Y) using tool 60.02. (4) If replacing: use tool 60.01 to unscrew old cooling tube. (5) Thread new HLN-G901Y into torch body finger-tight plus 1/4 turn. (6) Continue stack assembly. Never overtighten.
Indirectly, but critically. The cooling tube does not contact the plasma arc, but its coolant delivery performance determines electrode tip temperature. Proper cooling = stable hafnium emitter = consistent arc root = ISO 9013 Class 1 cut quality. Inadequate cooling causes arc root wander, increased dross, wider kerf, and tapered cuts. G901Y’s copper-silver alloy construction maximizes heat extraction at sustained 20–200A loads.
HALANSM® PN | Product | Suggestion |
HLN-G901Y | Cooling Tube 20–200A for PerCut450M | HALANSM® G901Y cooling tube for Kjellberg HiFocus280i 20–200A |
HLN-G002Y | Silver Electrode 20–200A O₂ | HALANSM® G002Y electrode for Kjellberg HiFocus130i O₂ plasma |
HLN-G2012Y | Nozzle O₂ 120A for PerCut450M | HALANSM® G2012Y O₂ nozzle for HiFocus280i 120A cutting |
HLN-G931Y | Cooling Tube 280–400A for PerCut450M | HALANSM® G931Y cooling tube for Kjellberg HiFocus440i 280–400A |
HLN-G501 | Protective Cap 20–200A | HALANSM® G501 protective cap for Kjellberg PerCut450M torch |
© HALANSM®. All rights reserved. | ISO 9001:2015 Certified Manufacturing